Gensets cost manufacturing unit 140kw 175kva electrical power yuchai diesel engine generator for income
WE ARE Manufacturing unit!
Products Functions:
one.We cooperate with renowned diesel engine -Powered by CZPT, Perkins Deutz , LovoL , Lister Petter, Doosan, Shangchai, Yarman, Foton-Isuzu, FAW, SDEC, Weichai, MTU, Ricardo, Jichai,And many others
2. Equipped with well-known Brushless alternator – Optional Stamford, Leroy Somer, Marathon, BOBIG, Mecc alte.
3. Outfitted with 50°C radiator with fan, ample engine cooling technique assure long time operating
4. Outfitted with advanced generator set control method, ATS program, remote control technique, parallel operation system, optional handle design, Deep sea, Smartgen , ComAp ,
5. Generator set use High-high quality steel are thickness canopy — 2MM to 6MM
six. Equipped with large density audio-absorbing substance — seem insulation, fireproofing
7. Generator geared up with 12V/ 24V DC battery with charger, battery connects wire.
eight. Generator equipped with 10-twelve several hours gasoline tank with gasoline indicator, prolonged time for operating.
nine. Large defend class manage box and energy output box. IP55, Waterproof, CZPT leakage defend, Breaker
ten. New style of turn-back again variety for air influx & air outlet which can reduce the sounds and boost engine performance.
11. Stunning & practicably layout, Bottom hole for forklift, Water outlet & oil outlet for easy maintenance
12. CZPT open up door on the two sides of the Gensets. Roomy doorways can check for each and every portion of the motor and alternator.
13. All new layout for diesel generator set of Silent, Supper silent, Soundproof, Trailer type, Container type.
14. Our generator set compliance with all main expectations, such as : GB/T2820, ISO8528,IEC34, CE, EPA Tier4 standard
Protection – Stability – Financial system – Reliability Energy
Our generator established compliance with all main requirements, such as : GB/T2820, ISO8528,IEC34, CE, EPA Tier4 standard
Controller Method
CZPT AMF management panel, such as electronic LED genset handle design: HGM6120U, DSE7320, DSE6571, AMF20, AMF25
Producing CZPT
GB/T2820, ISO,IEC34, CE, EPA Tier4 standard ,GB755,BS 5000,VDE 571, NEMA MG1-22,IEC34.
Solution Warranty plan
BOBIG goods has assure for a single calendar year or a thousand hours whichever get to very first from ex-factory date. During the guarantee period, we will provide the totally free simple-damageable spare components, triggered by our top quality of manufacturing or uncooked substance. Following expiration, our offers cost spare areas upkeep.
Genset Variety:
We can produce diesel generator from 5KW-2000KW for you.
We cooperate with renowned diesel motor -Run by CZPT,Yuchai,Xihu (West Lake) Dis.,Weichai, Deutz,HangCZPT,LovoL, DOOSAN, Shangchai, Yarman,FAW,Ricardo etc.
Voltage,frequency,tank capability,period(1phase or 3phase) and color can be made accord with your need,about more information details,a lot more versions and new value checklist,please speak to us.
BOBIG Power YUCHAI DIESEL GENERATOR | ||||||||
Product | BYU192 | silent sort | Open up sort | +ATS | ||||
CZPT electrical power (KW/KVA) | 140KW/175KVA | $8,962 | $eight,064 | $210 | ||||
Standby electricity (KW/KVA) | 154KW/92KVA | Freight: | ||||||
The purchase is greater,the price is reduce | ||||||||
CZPT description | ||||||||
1. Engine: YC6A230L-D20 YUCHAI | ||||||||
2. Alternator:BW-274G STAMFORD Kind | ||||||||
three. Controller: DEEPSEA/Smartgen | ||||||||
4. Digital velocity handle | ||||||||
5.:Frequency: fifty/60HZ | ||||||||
six. Rated speed: 1500rpm/1800rpm | ||||||||
seven. two*12V batteries, maintennance cost-free variety. | ||||||||
8. 24V cost dynamo. | ||||||||
nine. Outfitted with 10-12hours procedure base tank | ||||||||
ten. DIM: silent:3200*1200*1660mm ,open up: 2500*900*1760mm | ||||||||
11. Nobise stage: 69-72DB@7M ,if need decrease noise level,please contact us. | ||||||||
twelve. Bundle:Plywood circumstance | ||||||||
13. Radiator 50ºC max, supporters are pushed by belt with basic safety guard | ||||||||
14. Shipping time:10~fifteen doing work times following getting customers’ deposit | ||||||||
Photograph FOR REFERNCE ONLY | ||||||||
Motor requirements: | ||||||||
Engine model | YC6A230L-D20 | |||||||
Number of cylinders | 6 | |||||||
Cylinder arrangement | Vertical in line | |||||||
Cycle | four | |||||||
Aspiration | Turbo Intercooler | |||||||
Bore×Stroke(mm×mm) | 114×135 | |||||||
Displacement (Liter) | eight.three | |||||||
Compression Ratio | 16.five:1 | |||||||
CZPT electrical power/pace (kW/RPM) | one hundred fifty five/1500RPM | |||||||
Standby electrical power/velocity (kW/RPM) | a hundred and seventy/1500RPM | |||||||
Pace governor | mechanical | |||||||
Cooling method | Intercooler | |||||||
Coolant capacity (motor only) (L) | 12.three | |||||||
Steady speed droop (%) | 1% | |||||||
Whole lubrication technique capacity (L) | 24 | |||||||
Oil consumption (g/kw.h) | .15% of gasoline usage | |||||||
Fuel usage at 100% load (g/kw.h) | 230 | |||||||
Gas intake at 75% load (g/kw.h) | ||||||||
Gas use at fifty% load (g/kw.h) | ||||||||
CZPTter motor | 24V | |||||||
Dyanmo | 24V | |||||||
ALTERNATOR SPECIFICATION: | ||||||||
Compliance with GB755,BS5000,VDE571,NEMAMG1-22,IED34-one,CSA22.2 and AS1359 | ||||||||
Alternator product | BW-274G | |||||||
Exciter variety | Single bearing, Brushless, Self-thrilled | |||||||
Rated output primary power(KVA/KW) | 151kW | |||||||
Rated pace | 1500 RPM | |||||||
Rated frequency | 50 Hz | |||||||
Section | three | |||||||
Rated voltage | 220,230,240,380,four hundred,415v | |||||||
Existing(A) | 213 | |||||||
Electricity aspect | .eight | |||||||
Voltage alter range | ≥5% | |||||||
Voltage regulation NL-FL | ≤±1% | |||||||
Insulation grade | H | |||||||
Protection grade | IP23 | |||||||
Manage system | ||||||||
CZPT AMF control panel, like digital LED genset handle model: HGM6120U, DSE7320, DSE6571, AMF20, AMF25 | ||||||||
Defense | Parameter | Image | ||||||
Lower oil pressure | Volt | oil stress | ||||||
High h2o temp | existing | oil temp | ||||||
In excess of speed | electricity | electricity issue | ||||||
More than crank | pace | running time | ||||||
In excess of load | frequency | water temp | ||||||
More than/reduced volt | battery voltage | |||||||
In excess of/low frequency | ||||||||
battery demand failure |